EMX-8: Rainfall sensor is too sensitive

Created by Jean-Claude Hirzel, Modified on Wed, 25 Mar at 6:43 AM by Jean-Claude Hirzel

The ComObject "Precipitation" is too sensitive


Problem

The EMX rain sensor is often used for the FMX frost program. In the FMX, it is not possible to prevent frost from being triggered by cold temperatures and a few raindrops.



Workaround

On the EMX, starting with SW version 2.0 and application 2.0, the precipitation sensor sensitivity can be set to high (4s), medium (180s), and low (15 min).

Occurs in version

  • V1.6.V1.10
  • 160.V1.7.V1.10
  • 194.V1.8.V1.10
  • 195.V1.9.V1.10
  • 198.V1.10.V1.10
  • 199.V1.10.V1.11
  • 253.V1.10.V1.12
  • 254.V1.11.V1.12
  • 268.V1.11.V1.13
  • 269.V1.21.V1.13
  • 305.V1.22.V1.13