LUX strip, flashing LED on IBS
Problem
A Combio MVLED (or MLED) is installed in a cassette awning. Then, during IBS (programming the handheld transmitter to the Combio), the awning can be programmed, but the LEDs start flashing rapidly afterward... (cannot be programmed).
Workaround
The DC output of the Combio MVLED was connected to the originally installed transformer instead of directly to the LEDs (the transformer installed by Weinor was still connected in between; this happened, for example, when the MVLED was retrofitted externally to the two connection cables of a cassette awning using a design strip and cable set from the training center).
Remove the transformer, or connect the LEDs directly to the Combio MVLED.
Occurs in version
- .12.01.20
- 175.24.